Semikron SKKD101/16 Dual Diode Module

https://www.vpelectronics.in/web/image/product.template/30257/image_1920?unique=f0e05e0

SKKD101/16 (VP005092) Semikron Danfoss dual diode module, 1600 V, 143 A, isolated. Datasheet and quote from V P Electronics, Delhi.

₹ 810.00 810.0 INR ₹ 810.00 + GST 

Request for Quotation

  • Brand
  • Brand
  • Brand
  • Brand
  • Brand

This combination does not exist.

Terms and Conditions
100% genuine parts from authorised and verified sources
Ready stock: dispatch in 2–3 working days. Other items: delivery as confirmed in our quotation.

SKKD101/16 (VP005092): Semikron Danfoss Dual Diode Module, 1600 V, 143 A

1600 V143 ADual diodeSEMIPACK 1Isolated base

⬇ Download Datasheet (PDF)Get Quote / Bulk Price

Specifications · Applications · Selection tips · FAQ

The Semikron Danfoss SKKD101/16 is a dual rectifier diode module with two diodes in series (phase leg) on an isolated base. Two or three modules build single- or three-phase bridges with easy heat sink mounting. With 1600 V blocking voltage it suits 415 V and 440 V AC mains with good surge margin.

Key specifications

Repetitive peak reverse voltage VRRM1600 V
Non-repetitive peak voltage VRSM1700 V
ConfigurationDual rectifier diode module, isolated base
IFAV (sin. 180°)143 A (Tc = 85 °C) / 108 A (100 °C)
Surge current IFSM (10 ms)2600 A (25 °C) / 2210 A (130 °C)
I²t33800 A²s (25 °C)
Forward voltage VF1.65 V max (IF = 420 A, 25 °C)
Threshold / slope0.85 V / 2.05 mΩ max (130 °C)
Rth(j-c) (sin. 180°)0.2 K/W per chip, 0.1 K/W per module
Junction temperature–40 … +130 °C
Isolation Visol3000 V (1 min) / 3600 V (1 s)
Torque (heat sink M5 / terminals M5)4.25–5.75 Nm / 2.55–3.45 Nm
Weight75 g
PackageSEMIPACK 1

Source: Semikron Danfoss datasheet (Rev. 4.0, 23-04-2024). Check the full datasheet before design.

Typical applications

  • Single- and three-phase rectifier bridges
  • Battery chargers and DC power supplies
  • Welding and electroplating rectifiers
  • Freewheeling / input diodes in drives

Selection tips

  • Voltage: keep at least 2.5× margin over the peak line voltage.
  • Current: derate for higher case temperature and size the heat sink using the Rth values above.
  • Protect with semiconductor (high-speed) fuses; use thermal paste and the specified torque.

FAQ

Can SKKD101/16 be used on 415 V and 440 V AC mains?
Yes. With 1600 V repetitive voltage it has good margin for 415 V and 440 V AC lines; add MOV/RC protection where line transients are high.

Is the base plate isolated?
Yes. The base is isolated from the terminals, so it can share a common heat sink with other modules.

Do you supply the heat sink and accessories?
Yes. V P Electronics makes extruded and bonded-fin heat sinks and supplies fuses, snubber capacitors and firing cards.